Production Description
Rated Voltage: not specified, Rated temperature: 120°C.
Stranded, bare copper conductor, rang from 0.50 mm2 to 8 mm2.
Sole XLPVC (irradiated) insulation for automobile.
Passes JASO D 608- 92 flame test.
Uniform insulation thickness of wire to ensure easy stripping and cutting .
Resistant to acids, alkalis heat, cold, abrasions and oils.
Lead Free/RoHS* version is available, too, please contact us for more details.
*Lead Free/RoHS comply with European Union's(EU) Restriction of Hazardous Substances(Lead Free, Cadmium Free, Mercury
Free & Chromium Free, PBB & PBDE Free)
Application
For internal wiring of vehicles maters circuits and electrical equipment in high temperature condition.
AEX 120°C
|
Part
No.
|
Conductor
|
Insulation
|
Max
Resistance
At 20°C
|
Min
Insulation
Resistance
At 70°C
|
Dielectric
Strength
AC 1min
|
Specification
Sheet
|
|
|
Nom.
Area
|
No.
|
Dia.
|
Nom.
Thick.
|
Nom. Dia.
|
Max.
Dia.
|
|
|
Bare
Coppe
|
Tinned
Copper
|
|
|
mm2
|
mm
|
mm
|
mm
|
mm
|
mm
|
Ω /km
|
Ω . mm
|
V
|
|
|
200101
|
0.50f
|
20/0.18
|
1.00
|
0.50
|
2.00
|
2.20
|
36.70
|
38.60
|
109
|
1000
|
|
|
|
200102
|
0.50
|
7/0.32
|
1.00
|
2.00
|
2.20
|
32.70
|
34.60
|
|
|
|
200103
|
0.75f
|
30/0.18
|
1.20
|
2.20
|
2.40
|
24.40
|
25.80
|
|
|
|
200104
|
0.85
|
11/0.32
|
1.20
|
2.20
|
2.40
|
20.80
|
22.00
|
|
|
|
200105
|
1.25f
|
50/0.18
|
1.50
|
0.60
|
2.70
|
2.90
|
14.70
|
15.50
|
|
|
|
200106
|
1.25
|
16/0.32
|
1.50
|
2.70
|
2.90
|
14.30
|
15.10
|
|
|
|
200107
|
2.00
|
26/0.32
|
1.90
|
3.10
|
3.40
|
8.81
|
9.30
|
|
|
|
200108
|
3.00
|
41/0.32
|
2.40
|
0.70
|
3.80
|
4.10
|
5.59
|
5.90
|
|
|
|
200109
|
5.00
|
65/0.32
|
3.00
|
0.80
|
4.60
|
4.90
|
3.52
|
3.72
|
|
|
|
200110
|
8.00
|
50/0.45
|
3.70
|
0.80
|
5.30
|
5.60
|
2.32
|
2.45
|
|
|
|